Studying and evaluating the use of demineralised water in thermal power plants

  • Le Van Sy
  • Nguyen Phan Anh
  • Vu Minh Hung
  • Nguyen Ha Trung
Keywords: Demineralised water, DOE, thermal power plant, water consumption, water environment

Abstract

Demineralised water directly affects the cost of electricity production and the efficiency of the thermal power plant and depends on a lot of technological parameters and plant operation process. Researching and evaluating the use of demineralised water help save production costs and improve the efficiency of thermal power plants’ operation. In this paper, the operational parameters affecting

the amount of demineralised water were studied and analysed as the basis for the DOE analysis. The data input was investigated at the thermal power plants in Vietnam. The results of empirical statistical analysis identify the factors that influence the consumption of demineralised water, from which recommendations are made for measures to optimise the amount of demineralised water used in each plant.

References

1. Gary J.Stiege, James R.Longanbach, Michael D.Rutkowski. Power plant water usage and loss study. The United States Department of Energy National Energy Technology Laboratory. 2007.
2. Tạp chí Năng lượng Việt Nam. Nước tuần hoàn trực lưu nhà máy nhiệt điện: “Đóng thuế môi trường là vô lý”. 28/11/2012.
3. Ana Delgado, Howard J.Herzog. A simple model to help understand water use at power plants. Massachusetts Institute of Technology. 2012.
4. R.Ramkumar, A.Ragupathy. Optimization of cooling tower performance with different types of packings using Taguchi approach. Journal of the Brazilian Society of Mechanical Sciences and Engineering. 2015; 37: p. 929 - 936.
5. Ramkumar Ramakrishnan, Ragupathy Arumugam. Optimization of operating parameters and performance evaluation of forced draft cooling tower using response surface methodology (RSM) and artificial neural network (ANN). Journal of Mechanical Science and Technology. 2012; 26(5): p. 1643 - 1650.
6. Mustafa Bahadır Özdemir. Optimization of process parameters of ground source heat pumps for space heating applications with Taguchi method. Journal of Polytechnic. 2018; 21(4): p. 991 - 998.
7. M.Muthuraman. Reduction in power plant specific water consumption. International Power Plant O & M Conference. 2016.
8. Ram Kumar, Ragupathy Arumugam. Optimization of cooling tower performance analysis using Taguchi method. Thermal Science. 2013.
9. Central Electricity Authority New Delhi. Report on minimisation of water requirement in coal based thermal power stations. 2012.
10. T.Sudhakar, B.Anjaneya prasad, K.Prahladarao. Implementation of Six Sigma for improved performance in power plants. Journal of Mechanical and Civil Engineering. 2015; 12(5), p. 15 - 23.
11. Himanshu Kumar, Anurag Singh. DM make up water reduction in power plants using DMAIC methodology a Six Sigma approach. International Journal of Scientific and Research Publications. 2014; 4(2).
12. Prabhakar Kaushik, Dinesh Khanduja. Application of Six Sigma DMAIC methodology in thermal power plants: A case study. Total Quality Management. 2009; 20(2): p. 197 - 207.
13. Environmental Impact Assessment. Bangladesh: Power system expansion and efficiency improvement investment program (Tranche 3). Ashuganj 400MW Combined Cycle Power Plant (East). 2016.
Published
2020-03-31
How to Cite
Le Van Sy, Nguyen Phan Anh, Vu Minh Hung, & Nguyen Ha Trung. (2020). Studying and evaluating the use of demineralised water in thermal power plants. Petrovietnam Journal, 3, 48 - 58. https://doi.org/10.25073/petrovietnam journal.v3i0.267