Methods to detect corrosion under insulation

  • Pham Vu Dung
  • Nguyen Dinh Dung
  • Nguyen Thi Le Hien
Keywords: Corrosion under insulation, Radiography, Guided Wave Ultrasonic, Pulsed Eddy Current, Thermography, Neutron Backscatter

Abstract

Corrosion under insulation (CUI) is difficult to monitor and control. It is usually only detected when the insulation layer is removed for surveying or when an incident occurs. The study of corrosive detection under the insulation layer therefore plays a very important role in accurately determining the location of high risk of corrosion under insulation, which can help prevent breakdowns and minimise maintenance costs, contributing to the stable, effective and safe operation of the plant. The paper introduces methods for detecting corrosion under insulation such as Radiography, Guided Wave Ultrasonic, Pulsed Eddy Current, Thermography, Neutron Backscatter and Visual Inspection.

References

1. Nguyễn Văn Tư. Ăn mòn và bảo vệ vật liệu. Đại học Bách khoa Hà Nội.
2. NDT inspections. Corrosion Under Insulation and High Temperature Corrosion Conference.
3. ASNT. Ultrasonic testing. Nondestructive testing handbook, Third edition, Volum 7.
4. ASNT. Radiographic testing. Nondestructive testing handbook, Third edition, Volume 4.
5. Ivan C.Silva, Ygor T.B.Santos, Lurimar S.Batista, Claudia T.Farias. Corrosion inspection using pulsed eddy current. 11th European Conference on Non-Destructive Testing (ECNDT), Prague, Czech Republic. October 6 - 10, 2014.
6. TUV. Pulsed eddy current - detecting corrosion under isolation.
7. James Higgins. Corrosion under insulation - Detection methods and inspection. NACE meeting June 18, 2013.
8. API RP 583. Corrosion under insulation and fireproofing. 2014.
9. Pllock WI, Barnhart JM. Corrosion of metals under thermal insulation. ASTM STP 880. 1985.
10. NACE SP0198. Control of corrosion under thermal insulation and fireproofing materials - A systems approach. 2010.
11. Robin Ellis Jones. Use of microwaves for the detection of corrosion under insulation. Department of Mechanical Engineering, Imperial College London. 2012.
12. Dharma Abavarathna, William G.Ashbaugh, Russell D.Kanev, Nancy McGowan. Measurement of
corrosion under insulation and effectiveness of protective coatings.
13. Gary L.Bastin. Detecting corrosion under paints and insulation. PRCI pipelines research program meeting. 2011.
14. http://vnndt.com/san-pham/kiem-soat-an-monduong-ong33/kiem-soat-an-mon-duoi-lop-bao-on.html.
15. V.Mitchell Liss. Preventing corrosion under insulation. The National Board of Boiler and Pressure
Vessed Inspectors.
Published
2019-03-29
How to Cite
Pham Vu Dung, Nguyen Dinh Dung, & Nguyen Thi Le Hien. (2019). Methods to detect corrosion under insulation. Petrovietnam Journal, 3, 62-66. https://doi.org/10.25073/petrovietnam journal.v3i0.249
Section
Articles

Most read articles by the same author(s)

1 2 > >>